LevelScout 2X
Level & Temperature Data Logger
The Seametrics LevelSCOUT 2X is a compact, high-accuracy water level and temperature logger designed for groundwater, surface water and environmental monitoring applications.
Housed in rugged 316 stainless steel, the LevelSCOUT 2X combines an accurate pressure sensor, temperature measurement and integrated datalogger with capacity for up to 100,000 records. A narrow 22.2 mm diameter allows installation in monitoring wells and boreholes, while a replaceable battery and field-serviceable design make it particularly suitable for long-term monitoring programmes.
The LevelSCOUT 2X can operate as a standalone logger or integrate directly with telemetry systems using Modbus RTU RS485 or SDI-12 communications. Data configuration and download are handled using Seametrics Aqua4Plus software, with straightforward export for further analysis and reporting.
As an absolute pressure logger, water-level measurements can be barometrically compensated using a Seametrics BaroSCOUT 2X.
Key Features
Water level and temperature measurement
Up to ±0.05% full-scale level accuracy at 20°C
±0.1°C temperature accuracy
100,000-record internal memory
Logging intervals from one second
Compact 22.2 mm diameter
Rugged 316 stainless steel construction
Replaceable lithium battery
Approximately five-year battery life at four readings per hour
Modbus RTU RS485 and SDI-12 communications
Standalone or telemetry operation
Cableless and cabled configurations
Compatible with Aqua4Plus software
Serviceable design
Market leading three year warranty
Applications
Groundwater level monitoring
Surface water monitoring
Pumping and aquifer tests
Site investigation and remediation
Environmental monitoring
Tidal and surface water studies
Remote telemetry installations
Diameter | Ø22mm |
Length | 129mm Cableless 167mm Cabled |
Construction | 316 stainless steel (standard) or titanium with acetal and viton seals. |
Communications | RS485 Modbus and SDI-12 |
Memory capacity | 100,000 records |
Logging rate | User configurable to 1 per second |
Software / interface | Aqua4Plus Software (included) with Smart Comms cable |
Operating Temperature Range | -20 to 60ºC |
Storage Temperature Range | -40 to 80ºC |
Power | Replacement 2/3 AA 3.6V lithium battery |
Battery Life | Typically 5 years (at 4 readings per hour) |
Temperature Accuracy | ± 0.1° C |
Temperature Resolution | 0.01° C |
Pressure measurement ranges | 10m, 25m, 60m, 200m |
Pressure accuracy | ± 0.05% FS (@ 20° C) ± 0.10% FS (0° C to 40° C) |
Resolution | 0.0034% FS (typical) |
Maximum Operating Pressure | 1.1 x FS |